Review measurement

2026-06-07 12:11

Ozone Rush 5 ML (2018)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

C9
nom:
6912
rdg:
6879
diff:
-33
C10
nom:
6842
rdg:
6812
diff:
-30
C11
nom:
6748
rdg:
6722
diff:
-26
C12
nom:
6752
rdg:
6721
diff:
-31
C13
nom:
6661
rdg:
6629
diff:
-32
C14
nom:
6648
rdg:
6616
diff:
-32

Right riser

C9
nom:
6912
rdg:
6886
diff:
-26
C10
nom:
6842
rdg:
6826
diff:
-16
C11
nom:
6748
rdg:
6735
diff:
-13
C12
nom:
6752
rdg:
6737
diff:
-15
C13
nom:
6661
rdg:
6638
diff:
-23
C14
nom:
6648
rdg:
6623
diff:
-25

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7040.00
rdg:
7032.75
diff:
-7.25
nom:
6973.75
rdg:
6952.50
diff:
-21.25
nom:
7081.63
rdg:
7070.88
diff:
-10.75

Right riser

nom:
7191.75
rdg:
7181.25
diff:
-10.50
nom:
7113.25
rdg:
7096.75
diff:
-16.50
nom:
7245.50
rdg:
7217.00
diff:
-28.50
nom:
6771.50
rdg:
6766.83
diff:
-4.67
nom:
6713.17
rdg:
6695.67
diff:
-17.50
nom:
6760.50
rdg:
6740.83
diff:
-19.67

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-19) of the deviations of all measurements from their nominal values.

No issues were found