Review measurement
2026-04-12 20:23
Ozone Octane FLX 25 (2008)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A13
nom:
6138
rdg:
6684
diff:
+46
A14
nom:
5876
rdg:
6430
diff:
+54
B13
nom:
6096
rdg:
6638
diff:
+42
B14
nom:
5882
rdg:
6433
diff:
+51
C13
nom:
6105
rdg:
6650
diff:
+45
C14
nom:
5900
rdg:
6451
diff:
+51
D13
nom:
6149
rdg:
6701
diff:
+52
D14
nom:
5930
rdg:
6484
diff:
+54
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
nom:
7342.67
rdg:
7401.00
diff:
58.33
nom:
7267.17
rdg:
7322.50
diff:
55.33
nom:
7305.67
rdg:
7353.67
diff:
48.00
nom:
7412.33
rdg:
7457.33
diff:
45.00
nom:
7234.67
rdg:
7289.67
diff:
55.00
nom:
7176.33
rdg:
7229.33
diff:
53.00
nom:
7213.00
rdg:
7260.00
diff:
47.00
nom:
7307.00
rdg:
7349.33
diff:
42.33
Right riser
nom:
7234.67
rdg:
7289.00
diff:
54.33
nom:
7176.33
rdg:
7227.17
diff:
50.83
nom:
7213.00
rdg:
7256.33
diff:
43.33
nom:
7307.00
rdg:
7352.33
diff:
45.33
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found