Review measurement

2026-04-25 19:45

Ozone Swift 6 ML (2022)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
7001
rdg:
6946
diff:
-55
A10
nom:
6942
rdg:
6891
diff:
-51
A11
nom:
6851
rdg:
6801
diff:
-50
A12
nom:
6839
rdg:
6785
diff:
-54
A13
nom:
6738
rdg:
6692
diff:
-46
A14
nom:
6744
rdg:
6699
diff:
-45

Right riser

A9
nom:
7001
rdg:
6949
diff:
-52
A10
nom:
6942
rdg:
6895
diff:
-47
A11
nom:
6851
rdg:
6802
diff:
-49
A12
nom:
6839
rdg:
6790
diff:
-49
A13
nom:
6738
rdg:
6698
diff:
-40
A14
nom:
6744
rdg:
6696
diff:
-48

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
6852.50
rdg:
6802.33
diff:
-50.17
nom:
6845.17
rdg:
6807.17
diff:
-38.00

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-44) of the deviations of all measurements from their nominal values.

No issues were found